Flow Section Channels - Geometric Relationships
Area, wetted perimeter and hydraulic diameter for geometric sections like
- rectangular channels
- trapezoidal channels
- triangular channels
- circular channels
Rectangular Channel
Flow Area
Flow area of a rectangular channel:
A = b h (1)
where
A = flow area (m2, in2)
b = width of channel (m, in)
h = height of flow (m, in)
Wetted Perimeter
Wetted perimeter of a rectangular channel:
P = b + 2 h (1b)
where
P = wetted perimeter (m, in)
Hydraulic Radius
Hydraulic radius of a rectangular channel:
Rh = b h / (b + 2 h) (1c)
where
Rh = hydraulic radius (m, in)
Trapezoidal Channel
Flow Area
Flow area of a trapezoidal channel:
A = h (b + T) / 2 (2)
Wetted Perimeter
Wetted perimeter of a trapezoidal channel:
P = b + 2 (((T - b) / 2)2+ h2)1/2 (2b)
Hydraulic Radius
Hydraulic radius of a trapezoidal channel:
Rh = (h (b + T) / 2) / (b + 2 (((T - b) / 2)2+ h2)1/2) (2c)
Triangular Channel
Flow Area
Flow area of a triangular channel:
A = z h2 (3)
where
z = see figure above (m, in)
Wetted Perimeter
Wetted perimeter of a triangular channel:
P = 2 h (1 + z2)1/2 (3b)
Hydraulic Radius
Hydraulic radius of a triangular channel:
Rh = z h / 2 (1 + z2)1/2 (3c)
Circular Channel
Flow Area
Flow area of a circular channel:
A = D2 / 4 (α - sin(2 α) / 2) (4)
where
D = diameter of channel
α = cos-1 (1 - h / r)
Wetted Perimeter
Wetted perimeter of a circular channel:
P = α D (4b)
Hydraulic Radius
Hydraulic radius of a circular channel:
Rh = (D / 4) (1 - sin(2 α) / (2 α)) (4c)
Related Topics
• Fluid Mechanics
The study of fluids - liquids and gases. Involving velocity, pressure, density and temperature as functions of space and time.
Related Documents
California Pipe Flow Metering Method
Calculate the discharge length from the open end of a partially filled horizontal pipe.
Chezys Conduit Flow Equation
Calculating volume flow and velcity in open conduits.
Fluid Flow - Hydraulic Diameter
Calculate hydraulic diameter for pipes and ducts.
Manning's Formula and Gravity Flow
Calculate cross-sectional average velocity flow in open channels.
Rectangular Ducts - Hydraulic Diameter
Calculate hydraulic diameter for rectangular ducts - metric units.