Clo - Clothing and Thermal Insulation

Sponsored Links

The insulation effect of clothes can be measured in the unit "Icl, Clo" - where

1 Clo = 0.155 m2K/W

  • Clo = 0 - corresponds to a naked person
  • Clo = 1 - corresponds to the insulating value of clothing needed to maintain a person in comfort sitting at rest in a room at 21 ℃ (70 ℉) with air movement of 0.1 m/s and humidity less than 50% - typically a person wearing a business suit
Clo - Clothing and Thermal Insulation
ClothingInsulation
Icl, Clom2K/W
Nude 0 0
Underwear - pants Pantyhose 0.02 0.003
Panties 0.03 0.005
Briefs 0.04 0.006
Pants 1/2 long legs made of wool 0.06 0.009
Pants long legs 0.1 0.016
Underwear - shirts Bra 0.01 0.002
Shirt sleeveless 0.06 0.009
T-shirt 0.09 0.014
Shirt with long sleeves 0.12 0.019
Half-slip in nylon 0.14 0.022
Shirts Tube top 0.06 0.009
Short sleeve 0.09 0.029
Light blouse with long sleeves 0.15 0.023
Light shirt with long sleeves 0.20 0.031
Normal with long sleeves 0.25 0.039
Flannel shirt with long sleeves 0.30 0.047
Long sleeves with turtleneck blouse 0.34 0.053
Trousers Shorts 0.06 0.009
Walking shorts 0.11 0.017
Light trousers 0.20 0.031
Normal trousers 0.25 0.039
Flannel trousers 0.28 0.043
Overalls 0.28 0.043
Coveralls Daily wear, belted 0.49 0.076
Work 0.50 0.078
Highly-insulating coveralls Multi-component with filling 1.03 0.160
Fiber-pelt 1.13 0.175
Sweaters Sleeveless vest 0.12 0.019
Thin sweater 0.20 0.031
Long thin sleeves with turtleneck 0.26 0.040
Thick sweater 0.35 0.054
Long thick sleeves with turtleneck 0.37 0.057
Jacket Vest 0.13 0.020
Light summer jacket 0.25 0.039
Smock 0.30 0.047
Jacket 0.35 0.054
Coats and over-jackets and over-trousers Overalls multi-component 0.52 0.081
Down jacket 0.55 0.085
Coat 0.60 0.093
Parka 0.70 0.109
Sundries Socks 0.02 0.003
Thin soled shoes 0.02 0.003
Quilted fleece slippers 0.03 0.005
Thick soled shoes 0.04 0.006
Thick ankle socks 0.05 0.008
Boots 0.05 0.008
Thick long socks 0.10 0.016
Skirts, dresses Light skirt 15 cm. above knee 0.01 0.016
Light skirt 15 cm. below knee 0.18 0.028
Heavy skirt knee-length 0.25 0.039
Light dress sleeveless 0.25 0.039
Winter dress long sleeves 0.40 0.062
Sleepwear Under shorts 0.10 0.016
Short gown thin strap 0.15 0.023
Long gown long sleeve 0.30 0.047
Hospital gown 0.31 0.048
long pajamas with long sleeve 0.50 0.078
Body sleep with feet 0.72 0.112
Robes Long sleeve, wrap, short 0.41 0.064
Long sleeve, wrap, long 0.53 0.082

An overall insulation - or Clo - value can be calculated by simply taking the Clo value for each individual garment worn by a person and adding them together. The mean surface area of the human body is approximately 1.8 m2.

Example - Clothing Ensemble

Clothing Ensemble
ClothIcl
Briefs 0.04
Shoes 0.02
Socks 0.03
Short sleeve shirt 0.19
Straight trousers 0.15
Total 0.43
Sponsored Links

Related Topics

Physiology

Human physiology vs. air quality, comfort temperatures, activity and metabolic rates. Health effects of gases adn polutions like carbon monoxide and more.

Related Documents

Age and Physical Growth - Weight and Height

Age and typical physical growth of boys and girls - age 2 to 18 years.

Carbon Dioxide Concentration - Comfort Levels

CO2 acceptance and comfort level.

Carbon Dioxide Concentration in Rooms Occupied with People

Carbon dioxide concentration in a room may indicate air quality and ventilation system efficiency.

Clothing Sizes - US vs. UK and Europe

Comparing European, UK, US sizing in clothing, shoes, shirts and sweaters.

Clothing, Activity and Human Metabolism

Human metabolism at low and high activity with different levels of clothing.

Discomfort Index

Comfort vs. dry bulb, wet bulb and dew point temperature.

Globe Temperature

The resultant or globe temperature.

Heat Discomfort Zones

Maximum work load vs. temperature and relative humidity.

Heat Index vs. Humidity

The influence of humidity on the apparent temperature and the heat index.

Indoor Comfort Temperatures vs. Outdoor Temperatures

Recommended indoor comfort temperatures vs. outdoor temperatures.

Indoor Conditions - Summer or Winter

Recommended indoor design conditions summer or winter.

Indoor Design Temperatures

Recommended indoor temperatures in summer or winter.

Indoor Temperature and Humidity Loads

Calculate sensible and latent heat from persons, lights, electric equipment, machines, evaporation from water surfaces, polluting fluids and miscellaneous loads.

Insulation Materials - Operating Temperature Limits

Temperature limits for commonly used insulation materials.

Met - Human Metabolic Rates

Metabiolic Rate - Met - is used as a measuring unit for human body heat or power production.

Physiology - Activity and Metabolic Rates

Heat production from the human body vs. activity.

Predicted Mean Vote Index (PMV)

PMV index predicts mean comfort response of a larger group of people.

Recommended Relative Humidity

Recommended relative humidity level.

Sponsored Links

Search Engineering ToolBox

Search is the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics on the AMP pages. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.