Nominal
Pipe
Size
(inches)
Outside
Diameter
Schedule
5S10S40S80S
(mm)(inches)Wall Thickness and Weight
mm
(in)
kg/mmm
(in)
kg/mmm
(in)
kg/mmm
(in)
kg/m
1/8 10.3 0.405 - - 1.25
(0.049)
0.28 1.73
(0.068)
0.37 2.42
(0.095)
0.47
1/4 13.7 0.540 - - 1.66
(0.065)
0.49 2.24
(0.088)
0.63 3.03
(0.119)
0.80
3/8 17.2 0.675 - - 1.66
(0.065)
0.63 2.32
(0.091)
0.85 3.20
(0.126)
1.10
1/2 21.3 0.840 1.65
(0.065)
0.81 2.11
(0.083)
1.00 2.77
(0.109)
1.27 3.74
(0.147)
1.62
3/4 26.7 1.050 1.65
(0.065)
1.02 2.11
(0.083)
1.28 2.87
(0.113)
1.68 3.92
(0.154)
2.20
1 33.4 1.315 1.65
(0.065)
1.30 2.77
(0.109)
2.09 3.38
(0.133)
2.50 4.55
(0.179)
3.24
1 1/4 42.2 1.660 1.65
(0.065)
1.66 2.77
(0.109)
2.69 3.56
(0.140)
3.39 4.86
(0.191)
4.47
1 1/2 48.3 1.900 1.65
(0.065)
1.91 2.77
(0.109)
3.11 3.69
(0.145)
4.06 5.08
(0.200)
5.41
2 60.3 2.375 1.65
(0.065)
2.40 2.77
(0.109)
3.93 3.92
(0.154)
5.45 5.54
(0.218)
7.49
2 1/2 73.0 2.875 2.11
(0.083)
3.69 3.05
(0.120)
5.26 5.16
(0.203)
8.64 7.01
(0.276)
11.4
3 88.9 3.500 2.11
(0.083)
4.52 3.05
(0.120)
6.46 5.49
(0.216)
11.3 7.62
(0.300)
15.3
3 1/2 101.6 4.000 2.11
(0.083)
5.18 3.05
(0.120)
7.41 5.74
(0.226)
13.6 8.08
(0.318)
18.6
4 114.3 4.500 2.11
(0.083)
5.84 3.05
(0.120)
8.37 6.02
(0.237)
16.1 8.56
(0.337)
22.3
5 141.3 5.563 2.77
(0.109)
9.46 3.41
(0.134)
11.6 6.56
(0.258)
21.8 9.53
(0.375)
31.0
6 168.3 6.625 2.77
(0.109)
11.3 3.41
(0.134)
13.9 7.12
(0.280)
28.3 10.98
(0.432)
42.6
8 219.1 8.625 2.77
(0.109)
14.8 3.76
(0.148)
20.0 8.18
(0.322)
42.5 12.70
(0.500)
64.6
10 273.1 10.750 3.41
(0.134)
22.7 4.20
(0.165)
27.8 9.28
(0.365)
60.4 12.70
(0.500)
81.5
12 323.9 12.750 3.97
(0.156)
31.3 4.58
(0.180)
36.1 9.53
(0.375)
73.9 12.70
(0.500)
97.4