Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Densities of Aqueous Solutions of Inorganic Potassium Salts

Changes in density of aqueous solutions with changes in concentration at 20°C. Density of potassium salts in water is plotted as function of wt%, mol/kg water and mol/l solution.

Be aware of the concentration units in the figures:

wt%: Mass of solute/total mass of solution ×100%

mol/kg: Molality = moles of solute/kg of water 

mol/liter: Molarity = moles of solute/liter of solution

Values are tabulated below the figures.

See also density of aqueous solutions of inorganic chlorides, inorganic sodium salts, some other inorganic substances, organic acids and organic substances as sugars and alcohols.

Density of aqueous solutions of potassium salts



Density of aqueous solutions of potassium salts

Density of aqueous solutions of potassium salts

Density of aqueous solutions of potassium salts




Density of aqueous solutions at 20°C, given as g/cm3:

For full table with Potassium Hydrogen Carbonate, Potassium Hydrogen Phosphate, Potassium Hydroxide, Potassium Iodide, Potassium Nitrate, Potassium Permanganate and Potassium Sulfate - rotate the screen!

Aqueous Solutions of Inorganic Potassium Salts - Densities
Mass%Potassium bromidePotassium carbonatePotassium chloridePotassium dihydrogen phosphatePotassium hydrogen carbonatePotassium hydrogen phosphatePotassium hydroxidePotassium iodidePotassium nitratePotassium permanganatePotassium sulfate
1 1.0054 1.0072 1.0046 1.0053 1.0046 1.0068 1.0068 1.0056 1.0045 1.0051 1.0062
5 1.035 1.0437 1.0304 1.0342 1.031 1.0412 1.0419 1.036 1.0298 1.0322 1.0388
10 1.074 1.0904 1.0633 1.0703 1.065 1.068 1.0873 1.0762 1.0627 1.0806
20 1.1601 1.1898 1.1328 1.1372 1.1818 1.1659 1.1326
30 1.2593 1.2755 1.2813 1.2712
40 1.3746 1.4142 1.3881 1.3959
50 1.5404 1.5024
Density at 20°C, given as g/cm3


Conversion of the concentration from mass% to mol/kg (moles of solute/kg of water = molality):

For full table with Potassium Hydrogen Carbonate, Potassium Hydrogen Phosphate, Potassium Hydroxide, Potassium Iodide, Potassium Nitrate, Potassium Permanganate and Potassium Sulfate - rotate the screen!

Aqueous Solutions of Inorganic Potassium Salts - Densities - Conversion of the concentration from mass% to mol/kg
Mass%Potassium bromidePotassium carbonatePotassium chloridePotassium dihydrogen phosphatePotassium hydrogen carbonatePotassium hydrogen phosphatePotassium hydroxidePotassium iodidePotassium nitratePotassium permanganatePotassium sulfate
1 0.085 0.073 0.135 0.074 0.101 0.058 0.18 0.061 0.1 0.064 0.058
5 0.442 0.381 0.706 0.387 0.526 0.302 0.938 0.317 0.521 0.333 0.302
10 0.934 0.804 1.490 0.816 1.11 0.499 1.98 0.669 1.099 0.638
20 2.101 1.809 3.353 2.497 4.456 1.506 2.473
30 3.601 2.814 7.639 2.582
40 5.602 4.824 11.882 4.016
50 7.236 17.82
Molality at 20°C, given as mol/kg water


Conversion of the concentration from mass% to mol/liter (moles of solute/liter of solution = molarity):

For full table with Potassium Hydrogen Carbonate, Potassium Hydrogen Phosphate, Potassium Hydroxide, Potassium Iodide, Potassium Nitrate, Potassium Permanganate and Potassium Sulfate - rotate the screen!

Aqueous Solutions of Inorganic Potassium Salts - Densities - Conversion of the concentration from mass% to mol/liter
Mass%Potassium bromidePotassium carbonatePotassium chloridePotassium dihydrogen phosphatePotassium hydrogen carbonatePotassium hydrogen phosphatePotassium hydroxidePotassium iodidePotassium nitratePotassium permanganatePotassium sulfate
1 0.084 0.073 0.135 0.074 0.1 0.058 0.179 0.061 0.099 0.064 0.058
5 0.435 0.378 0.691 0.380 0.515 0.299 0.929 0.312 0.509 0.327 0.298
10 0.903 0.789 1.426 0.786 1.064 0.491 1.938 0.648 1.051 0.62
20 1.95 1.722 3.039 2.272 4.213 1.405 2.24
28 3.175 2.584 6.851 2.297
40 4.62 4.03 9.896 3.364
50 5.573 13.389
Molarity at 20°C, given as mol/l solution
3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.19.10

.
Cookie Settings