Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Water - Saturation Pressure and Specific Weight vs. Temperature

Vapor pressure and specific weight of water at temperatures ranging 32 to 212 oF - Imperial Units.

Saturation pressure (feet water column) and specific weight (pound per cubic foot) of water at temperatures ranging 32 to 212 oF are indicated below:

Water - Saturation Pressure and Specific Weight vs. Temperature
Temperature
- t -
(oF)
Specific Weight
- γ -
(lb/ft3)
Absolute Saturation Pressure
- p -
(ft H2O)
32 62.42 0.20
40 62.42 0.28
45 62.42 0.34
50 62.38 0.41
55 62.38 0.49
60 62.34 0.59
65 62.34 0.71
70 62.26 0.84
75 62.23 1.00
80 62.19 1.17
85 62.15 1.38
90 62.11 1.62
95 62.03 1.89
100 62.00 2.20
105 61.92 2.56
110 61.84 2.97
115 61.80 3.43
120 61.73 3.95
130 61.54 5.20
140 61.39 6.78
150 61.20 8.75
160 61.01 11.19
170 60.79 14.19
180 60.57 17.85
190 60.35 22.28
200 60.13 27.60
210 59.88 33.96
212 59.81 35.38
 
  • 1 ft H2O = 0.4335 psi = 2986  Pa
3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.4.10

.
Cookie Settings