Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Methane - Liquid vs. Gaseous Units

Convert between liquid and gaseous LNG and Methane units.

Commonly used units to measure Natural Gas or Methane - LNG - volume and weight:

Methane - Liquid vs. Gaseous Units
Multiply with
ToFrom
1 thermie 1061 therm 1061 bbl liquid1 m3 gas 1091 m3 liquid1 ft3 1061 ft3 liquid1 long ton liquid
long ton liquid 74.12 1868 0.0664 704374 0.4177 19.91 0.011826 1
ft3 liquid 6268 157985 5.615 59.56×106 35.315 1599 1 84.56
ft3 gas 3.92×106 98.79×106 3512 37.25×109 22090 106 625.43 52886
m3 liquid 177.44 4472 0.159 1.686×106 1 45.27 0.0283 2.394
m3 gas 105228 2.652×106 94.27 109 593 26847 16.789 1419.7
bbl liquid 1116.2 28132 1 10.61×106 6.29 284.785 0.1781 15.06
therm 39669 106 35.54 0.377×109 223.55 10121 6.329 535.2
th 106 25.207×106 859.8 9.503×109 5635.2 255115 159.54 13491
  • ft3 measured at 60 oF and 14.696 lbf/in2
  • m3 measured at 0 oC and 760 mmHg

Example - Converting 10 m3 methane liquid to m3 gas

From the table above - multiply (m3 liquid) with 593 to calculate (m3 gas) - as

qgas = 593 (10 m3 liquid)

        = 5930 (m3 gas)

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.4.10

.
Cookie Settings