Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Oil Pipes - Head Loss

Head or pressure loss due to friction in oil pipes - various viscosity and laminar flow.

Head or pressure loss in oil pipes with laminar flow can be calculated with the table below:

Viscosity (cSt) 4 25 45 250 500
Head loss  - h - 1.7×104 f / d4 11×104 f / d4 20×104 f / d4 110×104 f / d4 220×104 f / d4

where

h = head loss (moil/ mpipe) - meter oil per metre oil pipe - length of pipe includes allowances for bends, valves and fittings

f = flow of oil (liter/s)

d = internal diameter of pipe (mm)

The formula above is for laminar flow where Reynolds Number (Re) is less than 2300.

The Reynolds number can be calculated from the table below:

Viscosity (cSt) 4 25 45 250 500
Reynolds number 32×104 f / d 4.5×104 f / d 2.8×104 f / d 0.45×104 f / d 0.25×104 f / d

Oil Pipe Head Loss Calculator

The calculator is based on the equations above.

Viscosity (cSt)