Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Ethane Liquid - Thermal Properties

Density, specific heat and more of liquid ethane.

Thermal properties of liquid Ethane C2H6 at the vapor liquid phase boundary.

For full table with Density and Speed of Sound - rotate the screen!

Ethane Liquid - C2H6 - Thermal Properties
Temperature
- T -
(K)
Pressure
- p -
(kPa)
Enthalpy
- h -
(kJ/kg)
Entropy
- s -
(kJ/kgK)
Specific Heat Capacity
- cv -
(kJ/kgK)
Specific Heat
- cp -
(kJ/kgK)
Speed of Sound
- c -
(m/s)
Density
- ρ -
(kg/m3)
90.368
(triple point)
0.0011 -889 -5.06 1.61 2.33 2008 652
120 0.352 -821 -4.41 1.48 2.28 1794 619
150 9.64 -752 -3.90 1.44 2.33 1576 585
160 21.4 -729 -3.75 1.44 2.36 1501 574
170 42.8 -705 -3.60 1.43 2.39 1426 562
180 78.6 -681 -3.46 1.43 2.42 1350 550
184 98.3 -671 -3.41 1.44 2.44 1320 545
Standard Temperature and Pressure
186 109.4 -666 -3.38 1.44 2.45 1305 542
190 134.6 -656 -3.33 1.44 2.46 1274 537
200 217.2 -631 -3.21 1.44 2.51 1196 524
210 333.8 -606 -3.08 1.45 2.57 1117 510
220 492.1 -580 -2.96 1.47 2.65 1037 496
230 700.2 -553 -2.84 1.49 2.73 956 481
240 966.8 -525 -2.73 1.51 2.85 873 465
250 1301 -496 -2.61 1.53 2.99 788 448
260 1711 -465 -2.49 1.57 3.20 701 429
270 2210 -432 -2.38 1.61 3.49 609 408
280 2807 -397 -2.25 1.65 3.99 512 383
300 4357 -305 -1.95 1.91 10.02 275 304
305.322
(critical point)
4872 -230.7 -1.71 206

Ethane is an organic chemical compound with chemical formula C2H6.

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.4.10

.
Cookie Settings