Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Electrical Motors - Insulation Classes

Electrical motors NEMA temperature and insulation classes.

Electrical insulation systems are rated by standard NEMA (National Electrical Manufacturers Association) classifications according to maximum allowable operating temperature. Electrical motors will rapidly degrade if the internal temperatures exceeds the insulation temperature limits.

Electrical Motors - Temperature Limits vs. Insulation Classes
Insulation ClassTemperature Limit
(oC)
A1) 105
B1) 130
F2) 155
H2) 180

1) Hygroscopic insulation - avoided for open and outdoor locations - shortened lifetime if condensation in the insulation occurs

2) Non-hygroscopic insulation - preferred for open and outdoor locations, higher ambient temperatures ..

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.4.10

.
Cookie Settings