Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Compressed Air Pipe Lines - Pressure Loss vs. Capacity and Operating Pressure

Pressure drop in compressed air pipe lines.

Pressure drop in a compressed air pipe line depends on line pressure, air flow and size of pipe.

Pressure Loss in Schedule 40 Steel Pipes

Compressed Air Pipe Lines - Pressure Loss vs. Capacity and Operating Pressure
NPS
(in)
Air Flow1)
(SCFM)
Pressure Loss per 100 ft pipe (psi)
Line Pressure (psig)
5075100125
1/2 10 0.7 0.5 0.4 0.3
20 2.7 2.0 1.6 1.3
30 5.9 4.3 3.4 2.8
40 7.5 5.8 4.8
50 9.0 7.4
60 12.9 10.6
3/4 10 0.2 0.15
20 0.9 0.5 0.4 0.3
50 3.8 2.7 2.1 1.8
80 6.8 5.2 4.4
100 10.6 8.3 7.0
125 12.9 10.7
150 13.9
1 20 0.2 0.1 0.1
50 1.1 0.8 0.6 0.5
75 2.6 1.7 1.3 1.1
100 4.1 3.0 2.3 1.9
125 6.3 4.5 3.5 2.9
150 6.5 5.1 4.2
200 8.9 7.3
250 11.3
1 1/2 50 0.1
75 0.3 0.2 0.15 0.1
100 0.5 0.3 0.3 0.2
125 0.7 0.5 0.4 0.3
150 1.0 0.8 0.6 0.5
200 1.8 1.3 1.0 0.8
250 2.8 2.0 1.6 1.3
300 4.0 2.9 2.3 1.9
400 7.0 5.0 4.0 3.2
500 7.8 6.2 5.1
600 8.8 7.2
700 11.9 9.8
800 12.8
2 100 0.1
150 0.3 0.2 0.2 0.1
200 0.5 0.4 0.3 0.2
250 0.8 0.6 0.4 0.4
300 1.1 0.8 0.6 0.5
400 1.9 1.4 1.1 0.9
500 2.9 2.1 1.7 1.4
600 4.2 3.0 2.4 2.0
800 5.4 4.2 3.4
1000 8.3 6.5 5.3
1250 10.0 8.3
1500 11.9
2 1/2 150 0.1
200 0.2 0.15 0.1
250 0.3 0.2 0.2 0.1
300 0.5 0.3 0.3 0.2
400 0.8 0.6 0.5 0.4
500 1.2 0.9 0.4 0.6
600 1.7 1.3 1.0 0.8
800 3.0 2.2 1.7 1.4
1000 4.7 3.4 2.7 1.9
1250 7.5 5.4 4.2 3.5
1500 7.5 5.9 4.8
2000 10.3 8.5
2500 13.3
3 300 0.1 0.1
500 0.4 0.3 0.2 0.2
750 0.8 0.6 0.5 0.4
1000 1.5 1.1 0.8 0.7
1500 3.3 2.4 1.9 1.5
2000 5.9 4.2 3.3 2.7
2500 5.6 5.1 4.2
3000 9.4 7.4 5.1
3500 10.1 8.3
4000 13.1 10.8
4500 13.6
4 750 0.2 0.15 0.1
1000 0.4 0.3 0.2 0.2
1500 0.8 0.6 0.5 0.4
2000 1.5 1.1 0.8 0.7
2500 2.2 1.6 1.3 1.1
3000 3.2 2.3 1.8 1.5
4000 5.7 3.4 3.2 2.6
5000 6.3 5.0 4.1
6000 9.0 7.1 6.8
7000 9.7 7.9
8000 12.7 10.3

1) Free Air Inflow Volume Flow at Standard Conditions

Related Mobile Apps from The Engineering ToolBox Engineering Toolbox Apps

- free apps for offline use on mobile devices.

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.4.10

.
Cookie Settings